+ | Termination can be passive or active. Passive termination means that each signal line is terminated by two resistors, 220 Ω to TERMPOWER and 330 Ω to ground. Active termination means that there is a small voltage regulator which provides a +3.3 V supply. Each signal line is then terminated by a 110 Ω resistor to the +3.3 V supply. Active termination provides a better impedance match than passive termination because most flat ribbon cables have a characteristic impedance of approximately 110 Ω. Forced perfect (FPT) termination is similar to active termination, | ||
+ | |||
+ | In current practice most parallel SCSI buses are LVD and so require external, active termination. The usual termination circuit consists of a +3.3 V linear regulator and commercially available SCSI resistor network devices (not individual resistors). | ||
+ | |||